thiet-bi-do-diem-suong-dpt146-a1dbd110a0x-vaisala-vietnam-stc-vietnam.png
 
 
ĐẠI LÝ CHÍNH HÃNG VAISALA VIỆT NAM
 
 
 
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI3COMM4
MI3 series IR thermometer I/O box with USB 2.0 and RS485communications. Select the type of standard sensing heads listed above. For use over long distance or multi-drop networks and requires use of Smart RS485 converter.
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI310LTFCB3
Fast Response Mi3 Series Low Temperature Sensing Heads
0 - 1000°C (32 - 1832°F), 8 - 14 µm, 10:1, 20 msec, 3m (9.8') preinstalled cable (instead of standard 1m cable)
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI310G5SCB3
5 Micron Sensing Heads For Glass Applications
250 to 1650°C, 5 µm, D:S 10:1, 130 msec, 3m (9.8') preinstalled cable (instead of standard 1m cable)
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI310LTSCB15
-40 to 600°C (-40 to 1112°F), 8 - 14 µm, 10:1, 130 msec, 15m (49') preinstalled cable (instead of standard 1m cable)
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI310LTSCB30
-40 to 600°C (-40 to 1112°F), 8 - 14 µm, 10:1, 130 msec, 30m (98') preinstalled cable (instead of standard 1m cable)
100% USA Origin Fluke Process Instrument Vietnam Model: RAYMI3COMM
Installation of MI3 sensing head with MI3/MI3M communications box
100% Finland Origin Vaisala Vietnam Code: HMT330 7S1D001BXAA100A1DAABAA1
Humidity and Temperature Transmitter
Transmitter type: HMT337 for high humidities
Probe cables: Probe 2m +180C
Additional temperature probe: 2m, -70..+180°C 1/4 DIN Class B
Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No display, power supply : Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Analog output signals for Ch1: 0...100%RH
Analog output signals for Ch2: Special (pls confirm as placing order); Output units: Metric Units ; Option for module slot 1&2: no module; Cable bushings: Sealed Cable Gland M20x1.5
Transmitter installation: Wall Mounting Kit
Humidity sensor: Heated composite sensor
Sensor protection: PPS Grid with Steel Netting
No Installation Kit, No Accessories
100% Finland Origin Vaisala Vietnam Code: DPT146 A1DBD110A0X
DPT146 Dewpoint Transmitter
Mechanical connection: Glass Feed Through G1/2
Measurement parameters: Td/f, p, ppm, Td/f atm
Analog output Ch1 & Ch2 + RS-485 as standard: Analog Output 4...20mA
Analog output parameter or function for Ch1: Td Range  Td-80...+20C -112...+68F
Analog output parameter or function for Ch2: p absolute pressure
Output units: Metric Units
Cable for analog outputs and power supply (Port I): 0.3 m (1.0 ft) shielded M8 threaded connector
No Cable for RS485 line and power supply (Port II)
Installation accessories (ONLY for ISO1/2" thread)